Right, if our best regular conductors (used in your ohmmeter) are ~10^-8 and superconductivity is (by convention) less than 10^-11, one can see right away the simple regular methods won’t work and some cleverness is needed.
The conductors of your ohmmeter are not that important, though. You can work around that by using four-terminal sensing, and you can of course also calibrate your probes by directly touching them together. Even if your ohmmeter conductors have a resistance of several ohm, you could still get an accurate measurement if your tool has a high enough resolution.
A bigger issue is going to be sample size. A 1mm-diameter 1mm-long rod of silver has a resistance of about 20 μΩ (or 2e-5) at room temperature. That's already getting tricky to measure with lab-grade equipment without pushing insane currents through it, let alone anything even smaller. If you want to measure a 1m-diameter 1m-long silver rod (which would be 0.02μΩ or 2e-8) you could just push a few thousand amps through it and reliably measure that using a household multimeter in the mV range - but do that with a small sample and it'll evaporate.
> Even if your ohmmeter conductors have a resistance of several ohm, you could still get an accurate measurement if your tool has a high enough resolution.
Not that low in range though, you will end up seeing thermal noise that dwarfs your measurement.
> superconductivity is (by convention) less than 10^-11,
Ah, so you're saying that superconductivity is not actual zero resistance, but something close to it, and in fact only a factor of 1000x less resistive than the best conductor?
If that is so, this is something that I had previously thought would make a lot more sense to me.
But in that case it's not intuitive to me how SMES is possible with a 0% discharge rate. Shouldn't a significant fraction of the electrons looping around the coils be lost after many loops? (I know very little about electricity, as you can probably tell, never mind superconductors).